1 |
Gibson JN, Grant IC, W addell G. The Cochrane review of surgery for lumbar discpmlapse and degenerative lumbar spondylosis [J]. Spine, 1999, 24(17): 1820-1832.
|
2 |
Radeliff KE, Kepler CK, Jakoi A, et al. Adjacent segment disease in the lumbar spine following different treatment interventions [J]. Spine, 2013, 13(10): 1339-1349.
|
3 |
Agarwal N, Heary RF, Agarwal P. Adjacent-segment disease after thoracic pedicle screw fixation [J]. J Neurosurg Spine, 2018, 28(3): 280-286.
|
4 |
Wang YX, Zoltán KJ, Deng ML, et al. Lumbar degenerative spondylolisthesis epidemiology: A systematic review with a focus on gender-specific and age-specific prevalence [J]. J Orthop Translat, 2017, 11: 39-52.
|
5 |
Xia XP, Chen HL, Cheng HB. Prevalence of adjacent segment de generation after spine surgery: a systematic review and meta-analysis44 [J]. Spine (Phila Pa 1976), 2013, 38(7): 597-608.
|
6 |
Zhang Y, Zhang ZC, Li F, et al. Long-term outcome of dynesys dynamic stabilization for lumbar spinal stenosis. Chin Med J (Engl), 2018, 131(21): 2537-2543.
|
7 |
Jerry Y. Du, Paul D. Kiely, et al. Lateral lumbar interbody fusion with unilateral pedicle screw fixation for the treatment of adjacent segment disease: a preliminary report [J]. J Spine Surg, 2017, 3(3): 330-337.
|
8 |
Shinya O, Tomoya Y, Tomiya M, et al. Adjacent segment disease after posterior lumbar interbody fusion: a case series of 1000 patients [J]. Global Spine J, 2018, 8(7): 722-727.
|
9 |
Ali FO, Tunc O, Emrah E, et al. Lumbar single-level dynamic stabilization with semi-rigid and full dynamic systems: a retrospective clinical and radiological analysis of 71 patients [J]. Clin Orthop Surg, 2017, 9(3): 310-316.
|
10 |
Tuncay K, Ali Fahir O. Dynamic stabilization for challenging lumbar degenerative diseases of the spine: a review of the literature [J] .Adv Orthop, 2013, 2013: 753470.
|
11 |
Kurtz SM, Devine JN. PEEK Biomaterials in Trauma, Orthopedic, and Spinal Implants Biomaterials [J]. Biomaterials, 2007,28(32): 4845-4869.
|
12 |
Li C, Liu L, Shi JY, et al. Clinical and biomechanical researches of polyetheretherketone (PEEK)rods for semi-rigid lumbar fusion: a systematic review [J]. Neurosurg Rev, 2016, 41(2): 1-15.
|
13 |
Wang N, Xie H, Xi C, et al. A study to compare the efficacy of polyether ether ketone rod device with titanium devices in posterior spinal fusion in a canine mode [J]. J Orthop Surg Res, 2017, 12(1): 40.
|
14 |
Matthew SY, Daniel JC, Boyle CC. In vitro comparison of dynesys, peek, and titanium constructs in the lumbar spine [J]. Adv Orthop, 2015, 2015: 895931.
|
15 |
李世梁, 连育才, 孙海东, 等. PEEK棒与钛棒治疗腰椎管狭窄症的疗效对比 [J]. 中国矫形外杂志, 2018, 26(11): 983-987.
|
16 |
Jacques B, Bruno G, Gilles L. Flexible stabilisation of the degenerative lumbar spine using PEEK rods [J]. Adv Orthop, 2016, 2016: 7369409.
|
17 |
Kurtz SM, Lanman TH, Higgs G, et al. Retrieval analysis of PEEK rods for posterior fusion and motion preservation [J]. Eur Spine J, 2013, 22(12): 2752-2759.
|
18 |
Ji S, Sun C, Zhao J, et al. Comparison and analysis on mechanical property and machinability about polyetheretherketoneand carbon-fibers reinforced polyetheretherketone [J]. Materials (Basel), 2015, 8(7): 4118-4130.
|
19 |
Abdulhafez S, Sarah M, Feng T. Polyetheretherketone (PEEK) rods for lumbar fusion: a systematic review and meta-analysis [J]. Int J Spine Surg, 2018, 12(2): 190-200.
|
20 |
许小多, 于秀淳, 黄伟敏, 等. PEEK椎弓根螺钉内固定系统对椎间盘内压力变化影响的生物力学研究 [J].中国矫形外杂志, 2018, 26(11): 1041-1047.
|
21 |
Chou WK, Chien A, Wang JL. Biomechanieal analysis between PEEK and titanium screw-rods spinal construct subjected to fatigue loading [J]. J Spinal Disord Tech, 2015, 28(3): 121-125.
|