Home    中文  
 
  • Search
  • lucene Search
  • Citation
  • Fig/Tab
  • Adv Search
Just Accepted  |  Current Issue  |  Archive  |  Featured Articles  |  Most Read  |  Most Download  |  Most Cited

Chinese Journal of Clinicians(Electronic Edition) ›› 2017, Vol. 11 ›› Issue (12): 1926-1929. doi: 10.3877/cma.j.issn.1674-0785.2017.12.003

Special Issue:

• Clinical Researches • Previous Articles     Next Articles

Dignostic value of automated breast volume scanner versus mammography in breast neoplasms

Yuqin Huang1, Wu Chen1,(), Jiping Yan2, Chao Zhang2, Liqing Yang1, Nan Liang1, Fei Hao1   

  1. 1. Department of Ultrasound, the First Affiliated Hospital of Shanxi Medical University, Taiyuan 030001, China
    2. Department of Ultrasound, the People′s Hospital of Shanxi, Taiyuan 030001, China
  • Received:2017-03-09 Online:2017-06-15 Published:2017-06-15
  • Contact: Wu Chen
  • About author:
    Corresponding author: Chen Wu, Email:

Abstract:

Objective

To make a comparative study of the value of automated breast volume scanner (ABVS) versus mammography (MG) in the diagnosis of breast neoplasms.

Methods

One hundred and twenty female patients with 156 breast neoplasms diagnosed by conventional ultrasound, ABVS, and MG at our hospital from May 2016 to December 2016 were included in this study. Using the pathological results as the gold standard, the diagnostic efficiencies of conventional ultrasound, ABVS, and MG were comparatively analyzed.

Results

The sensitivity, specificity, accuracy, positive predictive value, and negative predictive value of conventional ultrasound in the diagnosis of breast neoplasms were 79.5%, 72.6%, 76.3%, 76.7%, and 75.7%, respectively; the corresponding values were 97.6%, 87.7%, 92.9%, 90.0%, and 97. 0% for ABVS, and 80.7%, 74.0%, 77.6%, 77.9%, and 77.1% for MG. The sensitivity, specificity, and accuracy of ABVS were significantly higher than those of conventional ultrasound (χ2= 11.65, 4.30, and 15.39, respectively, P<0.05). The sensitivity and accuracy of ABVS were significantly higher than those of MG (χ2= 10.35 and 13.49, respectively, P< 0.05). The diagnosis of breast calcification by ABVS and MG was comparatively consistent (Kappa= 0.79, P< 0.05).

Conclusion

The specific coronal plane image of ABVS can clearly show breast neoplasms. Compared to MG, ABVS performs better in terms of sensitivity and accuracy.

Key words: Ultrasonography, Mammography, Breast neoplasm, Automated breast volume scanner

京ICP 备07035254号-20
Copyright © Chinese Journal of Clinicians(Electronic Edition), All Rights Reserved.
Tel: 010-57830845 E-mail: zhlcyszz@cma.org.cn
Powered by Beijing Magtech Co. Ltd